Good lighting helps us see and makes a space comfortable. But light also influences our biological clock—and illuminance on a desk or floor tells only part of that story.
For this aspect of lighting, both the amount of light reaching our eyes and its spectrum matter. Melanopic EDI brings these two factors into one metric.
The Yuji Lux calculator lets you explore what this means for design: reach a daytime mEDI target with fewer lux at the eye, or retain more illumination in the evening while keeping mEDI low. Let’s look at three room examples.
Watch the comparison, then explore the three examples below.
Daytime: the same mEDI target, fewer lux at the eye
Start with the daytime office, where the aim is to reach the recommended daytime mEDI level while considering the room’s visual lighting needs. Both setups reach 250 lx mEDI. Essential High at 3000 K needs 457 lx at the eye; SunWave at 6500 K reaches the same target at 239 lx.

Essential High 3000 K at 77% dimming · SunWave 6500 K at 92%. The table also shows average horizontal illuminance at 0.80 m. View full-size comparison.
About 48% fewer eye-level lux for the same daytime mEDI.
That difference comes from spectrum. It gives the designer another variable to work with alongside light level and placement. The horizontal results remain visible too: 339 and 180 lx on the room plane. You can see both sides of the design problem instead of optimising one number in isolation.
Before bed: keep more light in the room
In the evening living room, the aim changes: keep melanopic exposure low while retaining useful illumination. Both choices deliver about 8.1 lx mEDI, below the evening target. But the average floor illuminance rises from roughly 25 to 36 lx with the Dim-to-FlameWarm setting.

SunWave 2700 K at 100% · Dim-to-FlameWarm at 43%, approximately 1920 K. View full-size comparison.
About 1.4× the average floor illuminance at the same low mEDI.
This is a more useful question than simply asking how far to dim the room: how much illumination can we retain by choosing a different spectrum? Try changing the Setup, then use Match Setup mEDI to see what the Alternative can provide.
At night: look at the floor, not just the melanopic number
The corridor starts at the stricter 1 lx mEDI setting. At that same melanopic level, Essential High and FlameWarm produce different floor results: approximately 1.1 and 4.0 lx.

Essential High 3000 K at 4% · FlameWarm at 13%. The calculator rounds the displayed floor values to whole lux. View full-size comparison.
About 3.6× the average floor illuminance at the same mEDI.
Across all three examples, the principle is the same: choose the spectrum for the task, then assess both the light reaching the eyes and the illumination in the room. Different spectra offer different ways to balance those needs.
Ratios use the underlying calculation values before display rounding.
Behind the numbers: a room model and a spectrum
To understand these differences, we need both parts introduced at the start: light level at the eye and spectrum. The examples combine DIALux room calculations with spectral data, linking a lighting choice to the result at the observer.
Where does the light land?


SunWave 6500 K at full output, maintenance factor 0.80. False colours show photopic illuminance in lux.
Locate the observer, then read the distribution
The vertical surface is a virtual calculation plane. It reveals how illuminance varies through the room; the eye-level result is evaluated separately at the observer.

The same DIALux room, with and without the vertical calculation surface. Numbers are lux; contour lines connect equal values.
At full output, this office calculation gives 261 lx at the eye and an average 197 lx on the horizontal room plane. Combined with the SunWave spectrum, that gives about 273 lx mEDI. The daytime screenshot above shows the same option dimmed to its 250 lx target.
Why colour temperature is only part of the story
Melanopic equivalent daylight illuminance, or mEDI, depends on both the illuminance reaching the eye and the spectrum. The ratio mDER describes the spectrum’s melanopic effectiveness per photopic lux:
mEDI = illuminance at the eye × mDER

SunWave spectral shapes at 2700 K and 6500 K. Each curve is normalised to its own peak; mDER is approximately 0.49 and 1.05 respectively.
A colour-temperature label alone cannot supply this spectral information. The calculator lets you see the spectrum alongside the room results, so the choice becomes something you can investigate rather than guess.
From a comparison to your lighting project
The next step is to apply the same questions to your space. Where are people working or relaxing? At what times? Which surfaces need light, and what reaches their eyes?
Send Yuji Lux your plans or dimensions, photographs and intended use. With your design team, we can assess eye-level and surface illuminance, develop the spectral and dimming scenarios, and select suitable LED strips, profiles, diffusers and controls. The proposal can connect the calculated result to the components, installation and quotation.
The calculator shows the possibilities. A project calculation turns them into a solution for your room.
About the results. These modelled examples use source spectra as an approximation at the eye; spectral changes through covers and reflections are not included. Interior renders are illustrative. Meeting mEDI alone does not establish visual comfort, energy savings, safe movement or a health outcome. Targets follow Brown et al. (2022) for healthy adults with regular daytime schedules: ≥250 lx mEDI by day, ≤10 for at least three hours before bed, ≤1 during sleep, and ≤10 for necessary nighttime visual activity. The corridor also offers that activity target. Metric definition: CIE S 026:2018.
Explore our circadian lighting guide or return to the Melanopic EDI Calculator.